Skip to content

SPIClient client response messages are shredded and useless, but here is how i fixed it. #7926

New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Open
tx0h opened this issue Mar 16, 2021 · 0 comments

Comments

@tx0h
Copy link

tx0h commented Mar 16, 2021

hi.

i know, this must sound strange to you hardcore, die hard SPI people. but i just disconnected CS and now the response message (all 32-byte) from slave to master will get delivered. it looks a bit funny from the logic analyzer perspective, because it can't detect the boundaries correctly but the data are where they should be.

if just two mcu's talk to each other via spi, this is a work around. i still have some hope left for a real fix but till then, the bluepill master is very happy with the ai thinker esp-12f.

oh, and the gpio15 problem got also solved, just leave it unconnected.

please suggest me a better solution &

thanx for your good work.

werheilthatrecht

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment